ADR 0014 - Connector-optional positioning

Decisionaccepted
On this page

Status

Accepted.

Context

DBOS has moved the Conductor client out of the MIT SDKs and into proprietary enterprise packages. The move is no longer only on the upstream main branches. It first shipped on 2026-10-15 and has continued since:

SDK First post-split release Current release Public package after the split
Go v1.7.0, 2026-10-15 v1.8.0, 2026-10-28 dbos/enterprise.go loader only
Python 3.3.0, 2026-10-15 3.4.0, 2026-10-28 dbos/_enterprise.py loader only
TypeScript 5.3.0, 2026-10-15 5.4.0, 2026-10-28 dist/src/enterprise.js loader only
Java no split 1.2.0, 2026-09-30 the public dev/dbos/transact/conductor/ tree is still present

The Python and npm packages publish under the DBOS Conductor Software License: dbos-enterprise 3.4.0 on PyPI and @dbos-inc/dbos-enterprise 5.4.0 on npm. The Go loader imports go.dbos.dev/dbos-enterprise-go, which Relay also does not inspect. Relay cannot inspect or functionally test any of them, and the licence forbids using their test results to build similar software.

This closes the premise behind the project's original positioning. Relay was presented as a zero-code-change drop-in: an unmodified application connects by changing its Conductor URL and key. That promise is a claim about the client half of the protocol. For a post-split SDK, the client half is now a proprietary package that Relay cannot verify. Keeping the promise would be a claim about someone else's code, which the project's citation rule exists to prevent.

The move does not close the integration surface that matters most. Every one of those releases still ships an MIT external client, DBOSClient in Python and TypeScript and dbos.Client in Go, with workflow queries, enqueue, send, cancel, resume, fork, rewind, queues, schedules, and application versions. The first post-split releases are at system database schema 123; the current releases are at schema 125. The application's durable state is still in its own database, written by MIT migrations. That surface is the foundation for ADR 0015.

Decision

Relay is positioned as an open control plane alternative for DBOS Transact applications, not as a drop-in replacement for the Conductor client after the split.

The support boundary is explicit:

  1. Attached mode remains supported for applications on SDK releases that still contain the public connector. The existing supported ceiling continues to apply: Go at most v1.6.0, Python at most 3.2.0, TypeScript at most 5.2.11, and Java without a ceiling. Java remains in this mode because it has not split; its current release is at system database schema 114.
  2. Direct mode is the path for applications on post-split SDK releases. It connects Relay to the application's system database through the MIT Go client. It is defined in ADR 0015 and covers schema 123 through 125 in its first version, which includes both post-split cohorts.
  3. A post-split SDK release is not supported in Attached mode. Relay does not claim that a proprietary connector will connect to Relay, and it does not build a surrogate connector as a foundation. A user who wants Attached mode on a post-split SDK must supply a connector they control, and the compatibility then belongs to that connector, not to Relay.
  4. A post-split release below the Direct schema floor is not supported by either mode. None exists today. If one appears, the options are an SDK upgrade or a user-supplied connector. Relay does not guess at an unknown schema.
  5. Parity claims name a public source. The OpenAPI documents served by the Conductor API, the MIT SDK sources while they remain public, the public DBOS documentation, and Relay's own tests are the permitted parity sources. Proprietary connector behaviour and proprietary server behaviour are not parity targets and are not tested.

The project continues to implement the Conductor executor protocol and HTTP API for the supported Attached window. That code is not discarded. It is the compatibility mode for existing deployments, for Java, and for users who want live executor telemetry. It is no longer the only road.

Consequences

  • The README, the goals page, the overview, and the landing page stop promising that an unmodified application on a current SDK connects by changing a URL. They describe the two modes and the boundary between them. The textual pages are updated with this decision; the landing page change carries rendered screenshots and follows as a separate visual change.
  • Supported SDKs records the ceiling as the Attached mode boundary and the Direct mode schema window. The Direct implementation, recovery path, and probe are covered by the data-plane test suite; the multi-SDK matrix extension follows.
  • Parity gaps that can only be observed by running the proprietary connector or server become documented gap entries. They are not open tasks someone is expected to close.
  • The project gains a second integration mode, which must be tested and documented with the same rigour as the first. A mode that is not in the conformance matrix is not supported.
  • The upstream ask narrows. The useful commitment is no longer "keep the connector open". It is "keep the external client MIT and keep the system database migrations public". That ask is recorded in the Direct mode decision.

Alternatives considered

  1. Keep the drop-in claim and rely on a surrogate connector. Rejected as a foundation. A surrogate is a loader-specific shim that upstream controls, requires an application dependency change, and must be maintained in four languages. It remains a user-side option, not a project promise.
  2. Fork the SDKs and keep the connector. Rejected. A fork carries the security and release burden of four SDKs and creates ecosystem confusion.
  3. Do nothing and wait for upstream. Rejected. The split has shipped. A plan that waits leaves the applications that have already moved without a supported path.