ADR 0015 - Direct mode through the system database
On this page
Status
Accepted. The engine, recovery path, and probe are implemented. The multi-SDK matrix extension follows.
Context
ADR 0014 withdraws the drop-in promise for post-split SDK releases and keeps Attached mode for pre-split SDKs and Java. That leaves a gap: an application on a post-split SDK still needs a control plane, and the connector that would carry it is proprietary.
The application does not need the connector to be durable. DBOS Transact writes every workflow, step, output, event, stream, queue, schedule, and application version to the application's system database. The connector is a transport for operations over that state. The state itself is open:
- The Go, Python, and TypeScript SDKs publish an MIT external client,
dbos.Clientin Go andDBOSClientin Python and TypeScript, with enqueue, send, cancel, resume, fork, rewind, workflow queries, queues, schedules, and application versions. - The first post-split releases are at system database schema 123: Go
v1.7.0, Python3.3.0, and TypeScript5.3.0. The current releases are at schema 125: Gov1.8.0, Python3.4.0, and TypeScript5.4.0. - Go SDK
v1.7.0requires schema 123, tolerates newer schemas, reads the out-of-line payload tables, supports PostgreSQL and SQLite system databases, and provides the MITdbos/internalsseam that exposesSystemDatabase.ReenqueueForRecovery. The SDK core runs the database-backed scheduler in a launched application; the external client creates and manages the schedule rows. It writes portable JSON when the input is aPortableWorkflowArgsvalue. - Go SDK
v1.8.0addsWithEnqueuePortableWorkflowas a convenience for the same portable JSON format, but it requires schema 125, so pinning it would strand the first post-split cohort.
Relay already permits this client for optional outage reads under ADR 0004. The change is one of role, not of access mechanism: the client moves from a fallback to a first-class integration.
The remaining gap is liveness. The database has no executor heartbeat. Relay can see workflow rows and their executor IDs, but it cannot tell a dead executor from a long durable sleep without an external signal. Recovery therefore needs a deployment-level input.
Decision
Relay supports a Direct mode in which it observes and controls an application through the application's own system database, using the official MIT Go client. Direct mode is a first-class mode, not a read-only fallback.
The rules are:
- Same access mechanism. Direct mode uses the official Go client and the
MIT
dbos/internalsseam. It does not issue raw SQL againstdbos.*tables and does not depend on the proprietary connector. ADR 0004 remains the access rule. This record supersedes ADR 0004 points 4 and 5 for Direct mode: the operation set is wider than the original six, and portable JSON supports a future enqueue, send, and event path that the original record deferred. This release does not expose those operations. The legacy fallback keeps the original scope until it is removed. - Read-only by default. A Direct connection is read-only unless the operator explicitly opts into read-write for that application. In read-write mode the allowlist is the client's operations: cancel, resume, fork, rewind, delete, schedule changes, setting the latest application version, and recovery. Enqueue, send, set-event, queue changes, export, import, and retention are not exposed by this release. The operator's read-write choice is the gate for Direct mutations; the legacy condition that mutations are allowed only when no executor is connected does not apply to Direct mode. A read-only Direct connection fails closed: the router does not retry the mutation over an executor socket to bypass the operator's choice. There is no DDL, no migration, and no query Relay invents.
- Recovery needs a liveness signal. Relay calls
ReenqueueForRecoveryfor a dead executor only when a deployment-level signal says the executor is gone. The supported signal comes from a smallrelay-probeprocess that shares the application process lifetime and reports its executor ID. A Kubernetes operator path is planned but has no published contract; it is not a supported path in this release. After re-enqueueing, Relay verifies that no PENDING work remains for the dead executor before deleting its record; a version mismatch keeps the record so the sweep can retry. Without a signal, Direct mode observes and controls but does not automatically recover, and it says so. - A bounded schema window. Direct mode v1 pins Go SDK
v1.7.0, which requires schema 123 and tolerates newer. The supported window is schema 123 through 125, which covers both post-split cohorts. The prototypes cover a 123 recovery run and a 125 read; the conformance matrix adds a 123 cell and a 125 cell, and 124 is covered by the client's migration tolerance and its index-only migrations. Newer schemas are tolerated by the client's migration check until the pin is raised, but they are not claimed as tested. A schema below 123 is refused with a problem response, not read with guessed columns. Applications below the floor use Attached mode. - Payload handling. Direct mode reads payloads in their stored format, including DBOS portable JSON, and never re-serializes a payload in another runtime's native format or unpickles untrusted data. Values it cannot decode safely are displayed as opaque. The v1.7.0 client supports portable JSON for a future enqueue path; this release does not expose enqueue, send, or set-event as REST operations.
- No per-language SDKs. Direct mode is implemented once in Relay's Go server. The optional probe, and a future operator, are deployment components, not application libraries. Relay does not publish Python, TypeScript, or Java packages.
- Supported application databases. PostgreSQL and SQLite are supported and tested as application system databases. SQLite-compatible engines such as Turso use the client's SQLite driver and are expected to work, but Relay does not test them; they are documented as compatible with a verification note.
- The client is a watched dependency. The implementation pins the Go SDK, vendors its source for reproducible builds, and runs a canary test against every new release before raising the pin. The project asks upstream to keep the external client MIT and the system database migrations public. If that changes, the contingency is a fork of the last MIT client or a narrow, client-mediated adapter, not a return to four connectors.
Why v1.7.0 rather than v1.8.0
The current client is not always the right client for a control plane. A
client that requires schema 125 cannot read the first post-split releases at
schema 123, and those releases have no connector to fall back to. v1.7.0
requires 123 and tolerates 125, so one client covers both cohorts. The cost is
that v1.8.0's WithEnqueuePortableWorkflow option is unavailable; v1.7.0
already supports the underlying portable JSON through PortableWorkflowArgs.
The pin is raised when the schema-123 cohort ages out of the support window, or when a needed fix exists only in a later client and the new client's floor does not strand a supported generation. Raising the pin is a scoped change with a fixture and a conformance run, not a routine dependency bump.
Schema floor and the legacy fallback
The previous data plane pinned Go SDK v1.3.0 to keep schema-107
applications working. Direct mode uses v1.7.0, which requires schema 123.
The two clients cannot coexist in one Go module.
Direct mode therefore retires the v1.3.0 fallback. The consequences are
deliberate:
- Applications at schema 123 through 125, including both post-split cohorts, are served by Direct mode.
- Applications below schema 123 are served by Attached mode. They keep the connector they already have.
- The out-of-line payload gap recorded in ADR 0013 does not apply to Direct mode. It remains only for the legacy fallback until that fallback is removed.
- The sample applications and the data-plane tests move to the supported schema generations and Direct mode in a separate implementation change. The examples that exist to prove Attached mode keep their pinned SDKs.
What Direct mode does not claim
- Live CPU, memory, and in-flight executor telemetry. Use a probe, OpenTelemetry, or Attached mode.
- Java applications at schema 114, the current Java
1.2.0generation. They use Attached mode until Java's schema aligns with the Direct window or an adapter exists. Attached recovery for Java is not yet verified; schema 19 belongs to Java0.8.0and older. - Tested support for SQLite-compatible engines other than SQLite itself. SQLite is supported and tested; compatible engines such as Turso use the client's SQLite driver but are not covered by Relay's test suite.
- Non-portable serializers for writes. They are read and displayed, not re-encoded.
- Automatic recovery without a liveness signal.
- Any behaviour of the proprietary connector or the proprietary server. None is inspected or tested.
Evidence
Two prototypes run on 2026-11-06 against the real Go SDK and an embedded SQLite system database proved the path without the connector. The implementation change turns them into reproducible tests in the repository.
Recovery on schema 123 with v1.7.0:
- A workflow ran one durable step and entered a durable sleep.
- The process was killed with
SIGKILL. The workflow row remainedPENDINGwith its completed step recorded and executor IDexec-dead. - A separate process opened the database through the Go client and called
ReenqueueForRecoveryforexec-dead. The row moved toENQUEUEDon_dbos_internal_queue. - A fresh executor with a different ID launched, dequeued the workflow, did
not re-run the completed step, and completed with output
done.
Cross-generation read with v1.7.0: a schema-125 database created by
v1.8.0 was opened by the v1.7.0 client and its workflow rows were read
successfully. This is the evidence for the 123-through-125 window.
The prototypes are not a substitute for the conformance test. They establish that the operation is possible with the public MIT client and no connector. The implementation change adds the hermetic tests to the repository, where they run in CI.
Consequences
- Relay gains a control-plane path that does not depend on the connector and works across languages, because the schema is shared.
- The data plane becomes a primary code path. It needs the same test rigour, observability, and documentation as the WebSocket path.
- The schema floor rises from 107 to 123. This is an intentional trade: a client that covers both post-split cohorts and reads out-of-line payloads is worth more than a fallback for applications that can still use Attached mode.
- Relay's dependency on the Go client becomes load-bearing. The release watch, the vendored source, and the upstream ask are part of the decision, not optional hygiene.
- The dashboard and REST API can serve a fleet with zero connected executors. The "no live executors" state becomes a normal state rather than an outage.
- Recovery is only as good as the liveness signal. The probe is therefore a first-class deliverable; the operator path remains planned. The dashboard must distinguish "no signal configured" from "executor dead".
Alternatives considered
- Pin
v1.8.0and support schema 125 only. Rejected. It strands the first post-split cohort at schema 123, which has no connector to fall back to. - Run two clients,
v1.7.0andv1.8.0, in separate processes. Rejected for v1. One client already covers both cohorts. Two clients add a second binary, a second connection pool, and a second failure mode for no capability the first version needs. - Use raw SQL for the whole data plane. Rejected. The MIT client already exposes the operations, keeps the provenance clean, and avoids a second implementation of DBOS semantics. A narrow adapter remains the contingency if the client becomes unavailable, and it stays client-mediated or a fork of the MIT client.
- Build surrogate connectors. Rejected as the foundation in ADR 0014. They remain a user-side option.
- Require Attached mode for recovery. Rejected. Recovery is the reason a control plane exists; leaving it to a proprietary client would make Direct mode a dashboard rather than a control plane.
Sources
dbos-inc/dbos-transact-golangtagv1.7.0, commit339705771d7e198c5bac9e213903820c0575e6c1, published 2026-10-15. The module containsdbos/enterprise.goand no Conductor client;dbos/dbos.godefinesClientandNewClient;dbos/workflow.godefinesPortableWorkflowArgshandling;dbos/internal/sysdb/system_database.godefinesReenqueueForRecovery; the migration list ends at 123.dbos-inc/dbos-transact-golangtagv1.8.0, commitf543516f2014d0c3d80a08dbe44fcc545c76a183, published 2026-10-28. The migration list ends at 125 andWithEnqueuePortableWorkflowis present.dbos-inc/dbos-transact-py3.3.0and3.4.0:dbos/_enterprise.pyis the loader,dbos/_client.pycontainsDBOSClient, and the migration lists end at 123 and 125 respectively.dbos-inc/dbos-transact-ts5.3.0and5.4.0:dist/src/enterprise.jsis the loader,dist/src/client.jscontainsDBOSClient, and the migration lists end at 123 and 125 respectively.dbos-inc/dbos-transact-java1.2.0:MINIMUM_SYSDB_VERSIONis 111 and the migration list ends at 114. The Conductor tree is still public.